The surgically altered breast: imaging technique and findings
Mini-Review Article

The surgically altered breast: imaging technique and findings

Poonpit Thongchai

Thanyarak Breast Center, Bangkoknoi, Bangkok, Thailand

Correspondence to: Dr. Poonpit Thongchai. Thanyarak Breast Center, Bangkoknoi, Bangkok 10700, Thailand. Email: poonpit.tx@gmail.com.

Abstract: Early diagnosis of breast cancer is the most importance factor that improve patient prognosis. Mammography has been proven in various randomized control trial as an effective screening tool for breast cancer. However, with the increasing of various breast surgical procedures such as breast augmentation, reduction mammoplasty and reconstruction, it may result in more challenging in surveillance and screening of the breast cancer. Imaging appearances of breast augmentation and other surgical altered breast are diverse. Understanding and familiar with the spectrum of imaging findings in the surgical altered breast may require to prevent image misinterpretation and which can result in delay diagnosis of malignancy and detection of locoregional recurrence.

Keywords: Mammogram; breast augmentation; reduction mammoplasty; breast cancer; breast reconstruction


Submitted Feb 26, 2014. Accepted for publication Feb 27, 2014.

doi: 10.3978/j.issn.2227-684X.2014.02.08


Breast cancer is the most common malignancy of women in most western countries including Thailand and other developing countries. According to the World Health Organization 521,000 died of breast cancer in 2012. In Thailand Breast Cancer is the most common malignancy found in women (37.5%) follow by cervical cancer (14.4%) and colorectal cancer (9.6%) (1).

Early Diagnosis of breast cancer is the most importance factor that improve prognosis. Mammography is currently the best imaging modality for early detection of breast cancer and the result of several studies have demonstrated that mammographic screening can decreased the mortality rate due to breast cancer (2,3).

As for breast augmentation surgery, there is no definite evidence that support the association between implants and cancer risk but they can interfere with cancer detection (4). The prevalence of breast cancer in patient with breast implant is similar to the one found in general population. The distribution of cancers by stage in women with breast implants is also similar to that of screened populations, and there is no significant difference in breast cancer survival rates between women with and those without implants (5).

There are many different methods used for augmentation and reconstruction of the breast, which can be divided into three different groups: (I) autogenous tissue transplantation; (II) injectable materials; and (III) implanted prostheses (6). Therefore imaging appearances of breast augmentation and other surgical altered breast are diverse and it is important to be familiar with the spectrum of these appearances to prevent image misinterpretation.

These articles will review technique and spectrum of imaging findings in post surgical altered breast including breast augmentation, reduction mammoplasty and conservatively treated breast.


Breast augmentation

Regular mammography screening after breast implant is recommended at interval appropriate for the woman’s age. Special views called implant-displaced (ID) views have been developed to better visualize the breast tissue anterior to a silicone breast implant.

For silicone gel and saline implant, there are numerous changes that can potentially occur after implant placement such as implant deformity, herniation or rupture of implant. The presence of silicone outside the implant is a clear proof of implant rupture visible on mammography. In general, MRI seems to be the best imaging modality to evaluating implant (Figures 1-4).

Figure 1 Normal appearance of subpectoral silicone implant. Implant-included mammogram, cradiocaudal (CC) (A) mediolateral oblique (MLO) (B). The pectoralis major muscle is visible just anterior to the implant. Implant-displaced (ID) view CC (C) and MLO (D) view. The breast has been pulled forward and implant was displaced backward.
Figure 2 Autologous myocutaneous flap performing for breast augmentation purposed. Bilateral digital mammogram cradiocaudal (CC) and mediolateral oblique (MLO) view show fat necrosis with dystrophic calcification bilaterally.
Figure 3 Normal bilateral transverse rectus abdominis myocutaneous (TRAM) flap. Bilateral Skin sparing mastectomy with the TRAM flap, mammographic findings. Both craniocaudal (CC) and mediolateral oblique (MLO) mammogram show a predominantly fatty appearance with minimal posteriorly located soft tissue density on the left side due to muscle component and postoperative scarring.
Figure 4 Silicone injections. Bilateral digital craniocaudal (CC) and mediolateral oblique (MLO) mammograms demonstrating silicone injections forming eggshell calcification surrouding granuloma throughout the breast and axilla, bilaterally.

Mammoplasty

Preoperative mammography for all women undergoing reduction mammoplasty is important to detect a lesion that requires further investigation or removal at the time of the reduction procedure.

Characteristic mammographic changes have been reported after reduction mammoplasty. Regardless of the exact type of reduction procedure performed, the changes reflect the removal and repositioning of breast tissue and the nipple-areolar complex (6) (Figure 5).

Figure 5 Bilateral craniocaudal (CC) and mediolateral oblique (MLO) mammogram 30 years after reduction mammoplasty in a 60-year-old woman. There is difficult to positioning for MLO projection, leading to suboptimal visualization of the pectoralis muscles. The breasts are higher and flatter in contour than normal breasts, and the nipple are elevated.

The common mammographic findings include:

  • Alteration of breast contour
  • Elevation of the nipple
  • Displacement of breast parenchyma
  • Architectural distortion
  • Skin thickening
  • Retroareolar fibrotic band
  • Disruption of subareolar ducts
  • Fat necrosis

Conservatively treated breast

In order to evaluate the treatment options the patient will undergo preoperative imaging. An intraoperative specimen radiography is useful to assessing adequacy of tumor resection and extention of calcification at the time the patient is in the operating room.

A post-operative imaging evaluation is then performed to look for residual tumor, calcification or tumor recurrence. The early diagnosis of recurrence is extremely importance because early detection of the recurrent tumor leads to improved survival likelihood (7) (Figure 6).

Figure 6 Spot magnification view of right mediolateral oblique (MLO) mammogram to evaluate tumor bed in patient with 1.5 year after breast-conserving therapy. A group dystrophic calcification is present at the lumpectomy site. Noting of fat density against background of architectural distortion and dystrophic calcification all these findings are most likely from fat necrosis.

For post surgical altered breast, it is helpful to have a mammogram performed 6-12 months after surgery to re-establish baseline findings.

It should be remembered that both benign and malignant processes can coexist in the treated breast. When it is not possible to determine whether the findings are due to carcinoma, fibrosis or other benign processes, biopsy should be performed.


Acknowledgements

The author would like to thank the kind support from Chairman of Thanyarak Breast Center, Siriraj Hospital, Dr. Tamnit Ansusinha and all colleagues.

Disclosure: The author declares no conflict of interest.


References

  1. National Cancer Institute, Department of Medical Services, Ministry of Public Health. Hospital-Based Cancer Registry, Thailand 2011.
  2. Kopans DB. Mammography screening is saving thousands of lives, but it survive medical malpractice? Radiology 2004;230:20-4. [PubMed]
  3. Tabár L, Vitak B, Chen HH, et al. Beyond randomized controlled trials: organized mammographic screening substantially reduces breast cancer mortality. Cancer 2001;91:1724-31. [PubMed]
  4. Kopans DB. Breast Imaging. 3rd ed. Philadelphia: Lippincott williams & wilkins, 2007.
  5. Bryant H, Brasher P. Breast implants and breast cancer--reanalysis of a linkage study. N Engl J Med 1995;332:1535-9. [PubMed]
  6. Bassett LW, Mahoney MC, Apple SK, et al. The surgically altered breast. Breast Imaging. Philadelphia: Saunders, 2011.
  7. Dershaw DD, Bracha A. The conservatively treated breast. Breast Imaging. Philadelphia: Saunders, 2011.
Cite this article as: Thongchai P. The surgically altered breast: imaging technique and findings. Gland Surgery 2014;3(1):48-50. doi: 10.3978/j.issn.2227-684X.2014.02.08

Download Citation